{"id":15538,"date":"2025-01-27T11:06:03","date_gmt":"2025-01-27T11:06:03","guid":{"rendered":"https:\/\/pse-eng.de\/?p=15538"},"modified":"2026-11-04T10:10:09","modified_gmt":"2026-11-04T10:10:09","slug":"ammoniakverfluessigungsanlage-projekt-in-deutschland-leverkusen","status":"publish","type":"post","link":"https:\/\/pse-eng.de\/en\/oel-gas-industrieanlagen\/ammoniakverfluessigungsanlage-projekt-in-deutschland-leverkusen\/","title":{"rendered":"AMMONIA LIQUEFACTION PLANT \u2013 PROJECT IN GERMANY, LEVERKUSEN\u00a0"},"content":{"rendered":"<p class=\"wp-block-paragraph\">The owner operates a cooling network in a chemical park in Leverkusen to supply the customers located there. The refrigeration system located in the company building consists of nine shell-and-tube heat exchangers, which are used as condensers (condensers), and 15 cooling water pumps. Age-related corrosion led to damage and leaks in the condensers. The constructive and spatially confined conditions do not allow the condensers to be rehabilitated on site. The customer therefore intends to replace all condensers and cooling water pumps.<\/p>\n\n\n\n<figure class=\"wp-block-image size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" width=\"565\" height=\"394\" src=\"https:\/\/pse-eng.de\/wp-content\/uploads\/2025\/01\/fhnh.jpg\" alt=\"\" class=\"wp-image-15539\" style=\"width:700px\" srcset=\"https:\/\/pse-eng.de\/wp-content\/uploads\/2025\/01\/fhnh.jpg 565w, https:\/\/pse-eng.de\/wp-content\/uploads\/2025\/01\/fhnh-300x209.jpg 300w, https:\/\/pse-eng.de\/wp-content\/uploads\/2025\/01\/fhnh-18x12.jpg 18w\" sizes=\"(max-width: 565px) 100vw, 565px\" \/><\/figure>\n\n\n\n<p class=\"wp-block-paragraph\">PSE was commissioned to plan the replacement of the shell-and-tube heat exchangers for the refrigeration lines with hybrid plate heat exchangers as well as new cooling water pumps with electric drive with an automatic backwash filter in the bypass flow, a sieve in the main stream and an automatic backwash filter for the supply of process water to the recooling plants and a venting apparatus, and to prepare corresponding tender documents for the implementation.<\/p>\n\n\n\n<p class=\"wp-block-paragraph\">The aim of the detailed planning is to create tender packages for each refrigeration line, which enables the customer to request and implement the renovation of a respective refrigeration line as required.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">THE TECHNICAL DATA OF THE PLANT<\/h2>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th>K\u00fchlwasserkreislauf<\/th><th>Wert<\/th><\/tr><\/thead><tbody><tr><td><strong>F\u00f6rderleistung<\/strong><\/td><td>15 \u00d7 1.300 m\u00b3\/h<\/td><\/tr><tr><td><strong>Betriebsdruck<\/strong><\/td><td>2,5 barg<\/td><\/tr><tr><td><strong>Anschlussleistung pro Pumpe<\/strong><\/td><td>15 \u00d7 70 kW<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table is-style-stripes\"><table class=\"has-fixed-layout\"><thead><tr><th>Ammoniakkreislauf<\/th><th>Wert<\/th><\/tr><\/thead><tbody><tr><td><strong>Produktionsleistung<\/strong><\/td><td>20.000 kg\/h<\/td><\/tr><tr><td><strong>Betriebsdruck<\/strong><\/td><td>14,5 barg<\/td><\/tr><\/tbody><\/table><\/figure>","protected":false},"excerpt":{"rendered":"<p>Der&nbsp;Anlagenbetreiber&nbsp;betreibt in einem Chemiepark in Leverkusen ein K\u00e4ltenetz zur Versorgung der dort ans\u00e4ssigen Kunden. Die im Betriebsgeb\u00e4ude befindliche K\u00e4lteanlage besteht unter anderem aus neun Rohrb\u00fcndelw\u00e4rmetauschern, die als Kondensatoren (Verfl\u00fcssiger) verwendet werden und 15 K\u00fchlwasserpumpen. Altersbedingte Korrosion f\u00fchrte zu Besch\u00e4digungen und Undichtigkeiten der Verfl\u00fcssiger. Die konstruktiven und r\u00e4umlich beengten Bedingungen erm\u00f6glichen es nicht die Verfl\u00fcssiger vor [&hellip;]<\/p>\n","protected":false},"author":7,"featured_media":15539,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[],"class_list":["post-15538","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-oel-gas-industrieanlagen"],"_links":{"self":[{"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/posts\/15538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/users\/7"}],"replies":[{"embeddable":true,"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/comments?post=15538"}],"version-history":[{"count":1,"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/posts\/15538\/revisions"}],"predecessor-version":[{"id":16611,"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/posts\/15538\/revisions\/16611"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/media\/15539"}],"wp:attachment":[{"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/media?parent=15538"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/categories?post=15538"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/pse-eng.de\/en\/wp-json\/wp\/v2\/tags?post=15538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}